Troubleshooting
To troubleshoot your media converter, perform the following:
1. Set the unit in the Link Test mode.
2. End stations used with the media converter must operate in the same
duplex mode (either both full-duplex or both half-duplex).
3. Verify that the twisted pair cable is Category 5.
4. Verify that proper fiber cable is being used: multimode for the
AT-MC101XL and AT-MC102XL, and single mode for the AT-MC103XL
and AT-MC103LH. Refer to Table 3 on page 10 for cable specifications
5. Verify that the near end node transmitter (TX) is connected to the far end
node receiver (RX) and vice versa on the fiber segment.
Technical Specifications
Table 2 lists the media converter technical specifications.
Specifications
Dimensions
Max. Operating temperature
Max. Storage temperature
Operating altitude
Humidity
EMI/RFI
Safety
Immunity
Power
Input supply voltage
Max. current
Power consumption
Table 2 Media Converter Technical Specifications
4.125 in W x 3.75 in D x 1.0 in H
(10.5 cm W x 9.5 cm D x 2.5 cm H)
0° C to 40° C (32° F to 104° F)
o
-20
C to 80
up to 10,000 ft (3,048 m)
5% to 80% (noncondensing)
meets FCC Class A, EN55022 Class A
EN60950, UL 1950, CSA 950
EN60825
EN50082-1 Immunity Standard
12 V DC +/-5%
500 mA
6W
o
C (-4° F to 176° F)
Installation Guide
9