16) Wash the bin control switch, water tank, fl oat switch, cube guide, silicone hose and
overflow pipe by using a nylon scouring pad, brushes and the cleaning solution. In
addition to the removed parts, also wash the bin liner and bracket (L) (R) with the
solution.
17) Discard the cleaning solution and rinse the parts thoroughly with water.

2. Sanitizing Procedure - Following Cleaning Procedure

1) Dilute approximately 0.5 fl . oz. (15 ml or 1 tbs) of a 5.25% sodium hypochlorite solution
(chlorine bleach) with 1 gallon (3.8 lit.) of warm water. Using a chlorine test strip or
other method, confi rm that you have a concentration of about 200 ppm.
2) Soak the removed parts from step 16 above in a clean container containing the
sanitizing solution. After allowing the parts to soak for 10 minutes, wash them with the
solution. Also wash the bin liner, bracket (L) (R) with the solution.
3) Discard the sanitizing solution and rinse the parts thoroughly with water.
4) Replace the removed parts in their correct positions in the reverse order of which they
were removed.
5) Dilute approximately 0.5 fl . oz. (15 ml or 1 tbs) of a 5.25% sodium hypochlorite solution
(chlorine bleach) with 1 gallon (3.8 lit.) of warm water. Using a chlorine test strip or
other method, confi rm that you have a concentration of about 200 ppm.
6) Pour the sanitizing solution into the water tank, and allow the sanitizer to sit for 10
minutes.
7) Move the control switch to the "WASH" position. Close the door.
8) After 15 minutes, move the control switch to the "OFF" position. Open the door.
9) Disconnect the silicone hose to drain the water. Reconnect the silicone hose back in its
correct position after all of the water has drained.
10) Repeat steps 5 through 9 one time. Repeat steps 8 through 11 in the Cleaning
Procedure three times to rinse thoroughly.
11) Flush the storage bin with water.
12) Move the control switch to the "ICE" position, and start the automatic icemaking
process.
13) Close the door. Replace the air fi lter in its correct position.
23