Sanitizing Procedure - Following Cleaning Procedure - Hoshizaki KM-1301SWH/3 Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1301SWH/3:
Table of Contents

Advertisement

2. Sanitizing Procedure - Following Cleaning Procedure

1) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with warm water. Refer to
the table.
Model
KM-1601 and Smaller
KM-1900 and Larger
2) Pour the sanitizing solution into the water tank.
3) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure the control switch is in the "WASH" position and the cleaning valve is
open.
4) Turn on the power supply to start the sanitizing process.
5) Turn off the power supply after 15 minutes.
6) Remove the front panel and the insulation panel.
7) Remove the drain plug. Allow the water tank to drain. Replace the drain plug and the
insulation panel in their correct positions.
8) Repeat steps 16 through 27 in "1. Cleaning Procedure" two times to rinse thoroughly.
9) Close the cleaning valve.
10) Move the control switch to the "ICE" position.
11) Replace the front panel in its correct position.
12) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
13) Turn on the power supply to start the automatic icemaking process.
5.25% Sodium Hypochlorite
Solution (Chlorine Bleach)
2.5 fl. oz. (74 ml)
3.5 fl. oz. (104 ml)
Warm Water
5 gal. (19 l)
7 gal. (26 l)
42

Advertisement

Table of Contents
loading

Table of Contents