Sanitizing Procedure - Following Cleaning Procedure - Hoshizaki KM1601SRH350 Service Manual

Stackable crescent cuber
Table of Contents

Advertisement

2. Sanitizing Procedure - Following Cleaning Procedure

1) KM1601SRH350: Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium
hypochlorite solution (chlorine bleach) with 5 gal. (19 l) of
warm water.
KM1900SAH350 and KM2100SRH350: Dilute 3.5 fl. oz. (104 ml or 7 tbs) of a 5.25%
sodium hyprochlorite solution (chlorine bleach) with 7 gal. (26 l) of warm water.
2) Pour the sanitizing solution into the water tank.
3) Replace the insulation panel and the front panel in their
correct positions.
Note: Make sure that the control switch is in the "WASH" position.
4) Turn on the power supply to start the sanitizing process.
5) Turn off the power supply after 15 minutes.
6) Remove the front panel and the insulation panel.
7) Remove the cap located on the front bottom part of the ice dropping hole. Drain the
water tank. Replace the cap and the insulation panel in their correct positions.
8) Repeat steps 15 through 25 in "Cleaning Procedure" two times to rinse thoroughly.
9) Move the control switch to the "ICE" position.
10) Replace the front panel in its correct position.
11) Clean the storage bin using a neutral cleaner. Rinse thoroughly after cleaning.
12) Turn on the power supply to start the automatic icemaking process.