Sanitizing Procedure - Following Cleaning Procedure - Hoshizaki SRK-15J Instruction Manual

Modular crescent cuber including condensing unit
Table of Contents

Advertisement

2. Sanitizing Procedure - Following Cleaning Procedure

1) Dilute 2 fl. oz. (60 ml or 4 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach)
with 4 gal. (15 l) of warm water.
2) Remove the front panel, insulation panel, and splash curtain if they are in their normal
positions.
3) Pour the sanitizing solution into the water tank.
4) Move the service switch to the "WASH" position.
5) Replace the splash curtain, insulation panel, and front panel in their correct positions.
6) Turn on the power supply to start the sanitizing process.
7) Turn off the power supply after 15 minutes. Remove the front panel.
8) Move the service switch to the "DRAIN" position.
9) Replace the front panel in its correct position, then turn on the power supply for
2 minutes.
10) Turn off the power supply. Remove the front panel.
11) Repeat steps 17 through 29 in "1. Cleaning Procedure" two times to rinse thoroughly.
12) Repeat steps 1 through 11 one more time.
13) Move the control switch to the "ICE" position.
14) Replace the front panel in its correct position.
15) Clean the dispenser unit/storage bin liner using a neutral cleaner. Rinse thoroughly after
cleaning.
16) Turn on the power supply to start the automatic icemaking process.
33