2. Sanitizing Procedure - Following Cleaning Procedure

1) Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 5 gal. (19 l) of warm water.
2) Remove the front, apron, top, left side, and side insulation panels if they are in their
normal positions.
3) Pour the sanitizing solution into the water tank.
4) Move the service switch to the "WASH" position.
5) Replace the side insulation, left side, top, apron, and front panels in their correct
positions.
6) Turn on the power supply to start the sanitizing process.
7) Turn off the power supply after 15 minutes. Remove the front panel.
8) Move the service switch to the "DRAIN" position.
9) Replace the front panel in its correct position, then turn on the power supply for
2 minutes to drain the water tank.
10) Turn off the power supply, then remove the front panel.
11) Repeat steps 17 through 25 in "III.B.1. Cleaning Procedure" two times to rinse
thoroughly.
12) Repeat steps 1 through 11 two more times.
13) Move the control switch to the "ICE" position.
14) Replace the front panel in its correct position.
15) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
16) Turn on the power supply to start the automatic icemaking process.