Natural Gas Conversion; Important - Jenn-Air JGD8348CDP Installation Instructions Manual

48" (121.9 cm) gas prostyle grill cooktop
Hide thumbs Also See for JGD8348CDP:
Table of Contents

Advertisement

Available languages

Available languages

To Convert Surface Burners
1. Remove Natural gas orifice hoods. Locate the LP gas orifice
hoods from the package attached to the outer plenum area of
this appliance.
2. To convert from Natural gas to LP gas, apply a ½" open-end
wrench to hex section of orifice hood. Turn counterclockwise
to remove.
3. Replace with correct color-coded orifice hoods (supplied).
See the "LP Gas Orifice Hood Chart." Turn clockwise to
install. Screw down the orifice hood so that the outer end of
the orifice hood is
" from the face of the mounting spud.
See the following illustration.
A
C
Turn
counterclockwise
to remove
A. ½" open-end wrench
B. Orifice hood
C. Mounting spud
LP Gas Orifice Hood Chart
Burner
BTU/hr
Left rear
7,500
Left front
7,500
Center rear
6,500
Center front
9,000
Right rear
6,500
Right front
9,000
4. Place Natural gas orifice in plastic parts bag for future use
and keep with package containing literature.
5. Repeat for the remaining burners.
Complete Installation
1. Refer to the "Make Gas Connection" section for properly
connecting the cooktop to the gas supply.
2. Refer to the "Burner Ignition" section for proper burner
ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop burner flame is very important.
The cooktop "low" burner flame should be a steady blue
flame approximately ¼" (0.64 cm) high.
3. Refer to the "Complete Installation" section of this manual to
complete this procedure.
Turn
clockwise
to tighten
B
Orifice
Diameter
Color
(inches)
#66
.033
Zinc
#66
.033
Zinc
#68
.031
Red
#63
.037
Blue
#68
.031
Red
#63
.037
Blue

Natural Gas Conversion

1. Turn manual shutoff valve to the closed position.
A
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position. Turn over the spring
retainer so the "NAT" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
E
D
A. Access cap
B. Gasket
C. Gas pressure regulator
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
B
C
A
B
C
D. NAT position
E. LP position
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

48" (121.9 cm)

Table of Contents