Page 7
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves.
Page 18
1. General Exhaust Duct Work Information Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats.
Page 19
NOTE: Where the exhaust duct work passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches larger (all the way around) than the duct. The duct must be centered within this opening. a. Outside Duct Work Protection 1) To protect the outside end of horizontal duct work from the weather, a 90°...
Page 23
ADG-75HS (G ADS-75 (S TEAM à Ã6XBÃT h q rqÃX v rà Ãs Ãv qv v qhyÃyr tu à yrÃuh à à s rr ...
Page 24
ADE-75 (E LECTRIC APPLIED VOLTAGE/PHASE...
WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten by using a fin comb which is available from local air conditioning supply house. 90 DAYS NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly. EVERY 6 MONTHS NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HAZARD.