Page 25
SINGLE-PHASE (1Ø) ELECTRICAL CONNECTIONS LEADS Black White Green Positive Neutral Ground...
Page 29
ADG-758DV (GAS) ADS-758DV (STEAM ) ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Page 31
6.0 - 12.0 inches W.C. Shaded areas are stated in metric equivalents kcal/hr MODEL Per Hour Rating NUMBER Rating AD-758DV 175,000 44,100 Shaded area is stated in metric equivalent TYPE OF GAS NATURAL 8.7 mb 14.92 - 29.9 mb TYPE OF GAS...
Page 34
OPERATING STEAM PRESSURE MAXIMUM MINIMUM HEAT INPUT (NORMAL LOAD) CONSUMPTION (APPROXIMATE) @ 125 PSI (8.62 BARS) Shaded areas are stated in metric equivalents 125 psig 100 psig* 6 Bhp 205 lbs/hr 862 kPa 689 kPa 92.98 kg/hr...
Page 36
COM PRESSED AIR SUPPLY NORMAL MINIMUM SUPPLY MAXIMUM SUPPLY Shaded areas are stated in metric equivalents AIR PRESSURE 80 PSI 5.51 bars 70 PSI 4.82 bars 90 PSI 6.21 bars...
Page 61