Kenmore Elite Oasis 110.7705 Series Use And Care Manual page 6

Canyon capacity gas dryer
Hide thumbs Also See for Elite Oasis 110.7705 Series:
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Plug into a grounded 3 prong outleto
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A 120 Volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
iNSTRUCTiONS
• For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion Hazard
Use a new CSA international approved
gas supply
line.
install a shut-off valve,
Securely
tighten
all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column,
Examples of a qualified
person
include:
licensed heating
personnel,
authorized
gas company personnel,
and
authorized
service personnel.
Failure to do so can result in death, explosion,
or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate
conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information
does not
agree with the type of gas available, contact your dealer or
call the phone numbers referenced on the front page of this
manual.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
Gas Supply Line:
1/2"IPS pipe is recommended.
%" approved tubing is acceptable for lengths under 20 ft
(6.1 m) if local codes and gas supplier permit.
Must include 1/s"NPT minimum plugged tapping accessible
for test gauge connection,
immediately upstream of the gas
connection to the dryer (see illustration).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

110.7706110.7707110.7708110.77097708 series

Table of Contents