What to do if the ADMIN password has been forgotten
If the ADMIN password becomes mislaid or forgotten, you will not be able
to access the AdderView Matrix to add or edit users and computer names.
This situation may be resolved by performing a complete reset to return the
AdderView Matrix to its factory default state.
IMPORTANT: A complete reset erases all the user names and computer
names that you have setup. You can only perform a complete reset if you
have access to both the front and the rear of the AdderView Matrix.
To perform a complete reset and return the AdderView Matrix to its
factory default state:
1 Power on the AdderView Matrix normally.
2 Whilst the AdderView Matrix is powered on move switch 2 on the rear panel
of the AdderView Matrix (labelled UPGRADE) to the ON (down) position.
3 Press the USER and the COMPUTER keys together.
4 The green USER display will show ' ' for a few seconds to confirm that a
reset is taking place.
5 Return switch 2 to the normal OFF position (up).
Ensuring that the serial port is available for other functions
The AdderView Matrix has a single RS232 serial port which can be used to:
• Control power switches,
• Send/receive configuration data, and
• Synchronise multiple video head switching.
The port can only be used for one of these tasks at any one time. For the latter
two functions to be possible, the Power Control option must be disabled.
To set the serial port for non-power control functions
Configuration
menu. Note: You must be logged-in as the
1 Display the
ADMIN user.
2 The 'Functions' option should be highlighted, press
3 Press
to display the 'Advanced Options' menu.
4 Highlight the 'Power Control' option and press
Control' option is 'DISABLED'. If not, highlight it and press
5 Press
to quit the screen and save the settings.
.
. Check that the 'Power
to change it.