Control Panel - CyberPower Paragon OL1000RMXL2U User Manual

Paragon series
Hide thumbs Also See for Paragon OL1000RMXL2U:
Table of Contents

Advertisement

1.3 Control panel

13
NO
13
ON / OFF.
14
BATT: Operation on battery power.
15
INV: Operation in ON-LINE mode (backup power available).
16
BYPASS: Operation on bypass (no backup power available).
17
OUTLET 2: Status of programmable outlet 2.
18
OUTLET 1: Status of programmable outlet 1.
: LED on indicates the outlet is supplied with power.
: LED flashing indicates the outlet status change in progress.
19
BZ STOP (TEST):
Lamp test or buzzer OFF.
Forced transfer to bypass and back by pressing the button
three times within five seconds.
20 LOAD: Hold down to display percentage of load by LEDs
Press 19 & 20 simultaneously at least three seconds to reset the "End of
battery life" alarm.
21
WIRING FAULT / Load 20%
22
BATT ALARM* / Load 50%
23
ALARM / Load 80%
24
OVER LOAD / Load 100%
* Flashing LED + buzzer: battery fault (battery must be replaced).
Flashing LED + long buzzer (once per hour): theoretical end of battery life
(replacement recommended).
14 15
16
17 18
Description
Alarms are indicated by LED flashing
(
remaining are indicated by LED
illuminated (
19
20
21 22
23 24
); percentage of load and battery
).
Device Overview 5
to
.
21
24

Advertisement