  • Page 1 Managed Switch User Manual Industrial Version 1.2 This document applied to models of MSM-508,MSM-508FC/FCS/FT April 29, 2008 Please print in double side TDRS4050601...
  • Page 2: Document Control

    Industrial Ethernet Layer 2 Managed Switch User Manual Document Control Date Author Version Description July 1, 2006 KC Chen First draft Dec 2, 2010 Jerry Chiu Add DI/O Wire Connection Jan 1, 2011 Jerry Chiu Modify jumper block label TDRS4050601...
  • Page 3: Copyright & Trademarks

    Industrial Ethernet Layer 2 Managed Switch User Manual Copyright & Trademarks All rig hts re se rv ed. No par t o f th is p ubl ica tio n ma y be repr odu ced , s to re d in a ret rie va l syst em, or tran smi tte d i n an y fo rm or by an y mean s, whe the r elec tro nic , m ec ha nica l, pho to co py ing, re cor din g or othe rwi se, wi th ou t th e p rio r w ri tt en p erm iss ion o f the...
  • Page 4: Disclaimer

    Industrial Ethernet Layer 2 Managed Switch User Manual Disclaimer Limited Warranty All pro duc ts ma nu fact ure d b y I CP D AS a re war ran te d agai nst de fec ti ve mat eri als fo r a peri od of one y ea r from th e d ate o f deli ver y t o t he o rigi nal pu rch as er .
  • Page 5: Preface

    How to Use this manual This manual is intended to help user quickly understanding and easily making use of MSM-508 (and other supported products), and the arrangement of chapters and sections follows the steps that user need to take. TDRS4050601...
  • Page 6: Table Of Contents

    Industrial Ethernet Layer 2 Managed Switch User Manual Contents Document Control..................i Copyright & Trademarks................ii Disclaimer....................iii Limited Warranty.......................iii Standards .........................iii Warning........................iii Safety........................iii Preface ...................... iv ICP DAS industrial Switch Series ................iv How to Use this manual....................iv Contents ....................v Acronyms ....................
  • Page 7 Industrial Ethernet Layer 2 Managed Switch User Manual On-line support ....................... 28 Contact Worldwide....................28 Appendix A ....................a Glossaries ......................... a Appendix B ....................c Specifications......................c Appendix C....................d Modbus Table ......................d Appendix E ....................f Ingress Protection (IP) ....................f Appendix F ....................
  • Page 8: Acronyms

    Industrial Ethernet Layer 2 Managed Switch User Manual Acronyms Acronym for Asynchronous Transfer Mode, a high performance networking technology based on the switching of fixed length, 53 byte cells. ATM switching supports the switching of voice, video, and data; also supports isochronous communication. Acronym for Bi-Polar Violation.
  • Page 9 Industrial Ethernet Layer 2 Managed Switch User Manual capabilities, and the logic and timing necessary to provide a standard EIA/TIA or CCITT interface. Converts signals between those used at the DTE's serial interface and bipolar signals used on the digital network.
  • Page 10 Industrial Ethernet Layer 2 Managed Switch User Manual Acronym for Pulse-Coded Modulation, a means of converting analog to digital form. RING Path or channel; usually electrical, where devices along the path receive transmissions sequentially from one device to the next along the ring.
  • Page 11: Introduction

    Industrial Ethernet Layer 2 Managed Switch User Manual Introduction Welcome to ICP DAS Managed Industrial Ethernet Switch one of the world’s best Industrial Ethernet Switch designed for connecting Ethernet Switch Ethernet-enabled devices in industrial field applications. This manual Industrial Ethernet is for the ICP DAS Managed Switch.
  • Page 12: Ethernet Switch

    Industrial Ethernet Layer 2 Managed Switch User Manual Ethernet Switch Ethernet is an ideal medium to transport large volumes of data, at speed, across great distances. Previously, multiple networks carrying specific protocols were installed side by side to carry out unique tasks. This inevitably led to project costs increasing as additional fiber optic or copper cables were installed to deal with the increasing volume of data.
  • Page 13 Industrial Ethernet Layer 2 Managed Switch User Manual like spanning tree, and SNMP to help with fault finding and system analysis were often employed to enhance network resilience. If a network failure occurred the IT department would casually look at repairing the equipment; there was no real rush as it was an office network.
  • Page 14: Industrial Fiber Optic

    Industrial Ethernet Layer 2 Managed Switch User Manual It is likely that these people will not be fully trained on Ethernet and the protocols that are in operation, nor will they fully understand the principles of SNMP etc. However, with a fault contact, fault LED’s and graphical interface implemented they have a multi-level approach to fault finding: The fault contact is hard-wired to an alarm on a control panel or as an input to a DCS.
  • Page 15: Industrial Vs. Commercial

    Industrial Ethernet Layer 2 Managed Switch User Manual Cost can be high relative to Fiber Industrial vs. Commercial Most process plants and factories have unique requirements for communications networks that differ from those of commercial grade networks. Industrial network components must withstand much harsher environmental conditions that can include extreme temperatures, lightning strikes, electromagnetic interference and, in many instances, installation in hazardous area locations.
  • Page 16: Appearance

    Industrial Ethernet Layer 2 Managed Switch User Manual Appearance Overview Dimensions The Managed Switch provides useful interfaces to configure the Front Panel switch functions. For hardware installation, we provide easy DIN rail On Case Quick Guide mounting, wall mounting modes, and come with aluminum case. All of connectors are well arranged on the front panel, so it is easier to stack with other devices and to maintain in a small installation space.
  • Page 17: Dimensions

    Industrial Ethernet Layer 2 Managed Switch User Manual Dimensions TDRS4050601...
  • Page 18: Front Panel

    Industrial Ethernet Layer 2 Managed Switch User Manual Front Panel Terminal block Left : Rignt : DO PWR 11. - DO GND 12. DI COM DO #2 13. DI #2 DO #1 14. DI #1 DO #0 15. DI #0 Relay (R.NO) 16.
  • Page 19: On Case Quick Guide

    Industrial Ethernet Layer 2 Managed Switch User Manual On Case Quick Guide LED status and Default Setting have been printed on left side of front panel. After acquainted with Managed Switch features, field engineers could deploy switches quickly by referencing those information. TDRS4050601...
  • Page 20: Hardware Installation

    Industrial Ethernet Layer 2 Managed Switch User Manual Hardware Installation For hardware installation, we provide both easy DIN rail mounting DIN-Rail Mounting and wall mounting modes. Installation Wall-Mounting Installation Overview Connecting Input Power Connecting Output Relay Managed Switch support redundant power, output relay and enhanced isolation to make device much robust.
  • Page 21: Din-Rail Mounting Installation

    Industrial Ethernet Layer 2 Managed Switch User Manual DIN-Rail Mounting Installation ® With ICPDAS patent DIN-Clip design, DIN-Rail mounting installation becomes very easy. Up Clip Following 3 steps completes installation. ➊ Pull the down rail clip out. Down Clip Push & Clip ➋...
  • Page 22: Wall-Mounting Installation

    Industrial Ethernet Layer 2 Managed Switch User Manual Wall-Mounting Installation ® With ICP DAS patent DIN-Clip design, Wall-Mounting installation becomes very easy. Following 1 step completes installation. ➊ Use the slotted holes at each corner of the wall-mounting clip to attach the unit to the wall or other flat surface.
  • Page 23: Connecting Input Power

    Industrial Ethernet Layer 2 Managed Switch User Manual Connecting Input Power IMPORTANT: It is good practice to turn off input and load power, and unplug the power terminal block before making wire connections. Otherwise, your screwdriver blade can inadvertently short your terminal connections to the grounded enclosure. ➊...
  • Page 24: Connecting Output Relay

    Industrial Ethernet Layer 2 Managed Switch User Manual Connecting Output Relay The diagram of output relay: ➊ Identify R.NO and R.COM contacts on terminal block. ➋ Insert the relayed device such as a light bulb or a buzzer pair of wire, and fastening the terminal screws to prevent the wires from coming loose.
  • Page 25: Connecting Digital Input & Output

    Industrial Ethernet Layer 2 Managed Switch User Manual Connecting Digital Input & Output The diagram of digital input and output: Wire Connection TDRS4050601...
  • Page 26 Industrial Ethernet Layer 2 Managed Switch User Manual ➊ Identify digital input and output contacts on terminal block. ➋ Fastening the terminal screws to prevent the wires from coming loose. TDRS4050601...
  • Page 27: Connecting Ethernet Ports

    Industrial Ethernet Layer 2 Managed Switch User Manual Connecting Ethernet Ports Managed Switch includes all RJ-45 ports with automatic MDI/MDI-X crossover, and automatic 10/100Mbps data rate sensing for 10Base-T or 100Base-TX connections. Automatic MDI/MDI-X crossover allows you to connect to other switches, hubs, or workstations, without regard to using straight-through or crossover cabling.
  • Page 28: Connecting Fiber Ports (Only For Models With Fiber Port)

    Industrial Ethernet Layer 2 Managed Switch User Manual Connecting Fiber Ports (only for models with fiber port) The automatic MDI/MDI-X crossover function does not apply to fiber connections, as these must be crossed over manually. To connect the fiber port on one switch to the fiber port of another switch, simply cross-connect the transmit channel at each end to the receive channel at the opposite end as illustrated in the figure below.
  • Page 29: Configuration

    Industrial Ethernet Layer 2 Managed Switch User Manual Configuration This chapter provide basic techniques to form a redundant ring on One Ring Topology your demand. Two Rings Coupling Two Rings Coupling with Overview Two Phase Recovering To successfully form a robust industrial Ethernet network, the designing of network pattern is the most important stage.
  • Page 30: One Ring Topology

    Industrial Ethernet Layer 2 Managed Switch User Manual One Ring Topology A ring topology ensures the network having one more chance to keep connection alive when any connection between 2 switches (nodes) has been broken inside the ring. When we have formed a ring network, the focal point (master) will choose any one and only one path as Redundant Path.
  • Page 31: Two Rings Coupling

    Industrial Ethernet Layer 2 Managed Switch User Manual Two Rings Coupling As a ring network is a small group of switches by geography, functionalities, or subsystem, 2 or more rings could be coupled together to form a whole picture of industrial network for an integrated system.
  • Page 32: Two Rings Coupling With Two Phase Recovering

    Industrial Ethernet Layer 2 Managed Switch User Manual Two Rings Coupling with Two Phase Recovering Redundant coupling gives one more chance to keep connection alive when any connection between 2 rings has been broken. It is much safe than Single Coupling, but it takes 3 more switches to form Redundant Coupling.
  • Page 33: Troubleshooting

    Industrial Ethernet Layer 2 Managed Switch User Manual Troubleshooting Overview This chapter includes some information for general troubleshooting No Power to the Switch as follows: No Link Light on a Switch Port No Power to the Switch Master LED Keep on No Link Light on a Switch Port Flashing Master LED Keep on Flashing...
  • Page 34: No Power To The Switch

    Industrial Ethernet Layer 2 Managed Switch User Manual No power to the switch. • Check for faulty power cord. • Check for loose or broken power connections. • Check connections to ensure the power and ground are attached to the correct terminals. •...
  • Page 35: Service Information

    Industrial Ethernet Layer 2 Managed Switch User Manual Service Information We sincerely hope that you never experience a problem with any ICP DAS product. If you do need service, call ICP DAS at 886-3-5973366 and ask for Applications Engineering. Our well-trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call.
  • Page 36: Glossaries

    Industrial Ethernet Layer 2 Managed Switch User Manual Appendix A Glossaries ANSI X3T9 Commonly referred to as FDDI. A local area network protocol that operates at 100Mbps. Asynchronous Having a variable time interval between successive data or information in the form of characters, operations, events.
  • Page 37 Industrial Ethernet Layer 2 Managed Switch User Manual A device for local area networks (LANs) that is used to interconnect multiple devices over an internal bus. Jitter Aka. phase jitter, caused by power line harmonics and perceived in the form of minor phase changes.
  • Page 38: Specifications

    Industrial Ethernet Layer 2 Managed Switch User Manual Appendix B Specifications Ethernet switch type RJ45 ports (shielded) RJ45 speed (auto-negotiating) RJ45 auto-mdi/mdi-x Ethernet protocols supported Memory bandwidth Completely compliant Full or half duplex operation MAC addresses supported Ethernet isolation Required supply voltage Power input isolation Power consumption (Redundant input terminals)
  • Page 39: Modbus Table

    Industrial Ethernet Layer 2 Managed Switch User Manual Appendix C Modbus Table Switch Status Address Status Address 10000 Ring Pair 1 Enable 10004 Power 1 Fail 10001 Ring Pair 2 Enable 10005 Power 2 Fail 10002 0 : Ring Protocol 10006 Relay output 1 : Spanning Tree Protocol...
  • Page 40 Industrial Ethernet Layer 2 Managed Switch User Manual Digital Input & Output Address Status Address 10057 Digital Input channel 1 00001 Digital Output channel 1 10058 Digital Input channel 2 00002 Digital Output channel 2 10059 Digital Input channel 3 00003 Digital Output channel 3 10060...
  • Page 41: Ingress Protection (Ip)

    Industrial Ethernet Layer 2 Managed Switch User Manual Appendix E Ingress Protection (IP) An IP number is used to specify the environmental protection of enclosures around electronic equipment. These ratings are determined by specific tests. The IP number is composed of two numbers, the first referring to the protection against solid objects and the second against liquids.
  • Page 42: Accessories

    Industrial Ethernet Layer 2 Managed Switch User Manual Appendix F Accessories Power Supply (KA-52F/DIN-KA52F) Features & Specifications Input Range : 100~250AC Input Frequency : 50Hz to 60 Hz Output : 24Vdc/1Amp max. Output Power : 25Watts Operating Temperature:0 to 70℃ Storage Temperature : -40 to 85 ℃...

This manual is also suitable for:

Msm-508fcMsm-508fcsMsm-508f tMsm-508ft

Table of Contents