Download Print this page

Before You Begin; Specification - Kohler 8022A Installation And User Manual

Watertile showerhead

Advertisement

All information is based on the latest product information available at the time
of publication. Kohler Co. reserves the right to make changes in product
characteristics, packaging, or availability at any time without notice.
Please leave these instructions for the consumer.
NOTES:
1. Flush the water supply pipes thoroughly to remove any debris.
2. An in line water filter must be used with this product.
3. Inspect the supply pipes for damage. Replace as necessary.
4. Observe local plumbing codes.
5. The recommended working pressure for the shower head is 150KPa to
500KPa. If the pressure exceeds 500KPa a pressure reducer is required.
6. Maximum water and environmental temperature for the shower head is
60C. Note: If a heater is present, make sure to keep it away from the shower
head as otherwise the environmental temperature may exceed 60C.
7. All installations should comply with the relevant requirements of AS/NZS
3500 and AS/NZS 6400.
121
8033A
Pressures For multiple outlets an operating pressure of 3.0 bar or greater is
recommended to ensure optimum performance.
Plumbing Connections (Hot) and Cold (C) inlets must be connected to the
correct inlet supplies.
Building in Depth
a minimum stud wall cavity of 100 mm is provided to ease installation.
1063864-AN2-E
17/02/12

BEFORE YOU BEGIN

DIMENSIONS
121
127
8022A

SPECIFICATION

Minimum building in depth is 79 mm. It is recommended that
127
2

Advertisement

loading

This manual is also suitable for:

8023a