8.
ADJUSTMENTS
MAXIMUM WATER
TEMPERATURE ADJUSTMENT
Remove the handle and face plate
from the valve, if installed.
Turn the valve stem fully
clockwise to get maximum hot
water flow.
To adjust the maximum
temperature, slide the stem
O ring out of groove and part way
up valve stem. Move the upper
limit stop ring part way up the
valve stem. Rotate the valve stem
until the desired maximum water
temperature is reached. Rotate
lower limit stop ring until it
contacts the tab. Slide the upper
limit stop down the valve stem to
engage the lower limit stop. Slide
the O ring into the valve stem
groove.
Rotate the valve stem
counterclockwise to shut the
water off. Reinstall the handle
and face plate.
CE
114552 2
Tab
Lower Limit
Stop
Groove
O Ring
Kohler Co., Kohler, WI
10
Upper Limit
Stop
Valve
Stem