9. Unplug the USB cable.
10. Remove the screws from the USB connector and remove it.
11. Attach the new USB cable to the connector and tighten the screws.
12. Connect the USB cable.
13. Slide the turret side cover back into place. Be sure the attachment
plate is seated properly. Press and hold the turret side cover in
place and tighten the screws to secure the front and side covers.
14. Reconnect the ribbon cable by pressing it all the way into the
connector until it snaps and clamps into place.