CS1708i / CS1716i User Manual
Maintenance
The Maintenance page allows the Administrator to upgrade the CS1708i /
CS1716i's firmware, and to backup and restore the CS1708i / CS1716i's
configuration settings, user accounts, and port names.
Firmware Upgrade
As new versions of the CS1708i / CS1716i firmware become available, they
can be downloaded from our website. Check the website regularly to find the
latest information and packages.
Note: The firmware upgrade described in this section refers to the CS1708i /
CS1716i's icard firmware. Each time you perform this upgrade, you
must also upgrade the mainboard firmware (see Chapter 12, The
Firmware Upgrade Utility).
To upgrade the icard firmware, do the following:
1. Download the new firmware file to your computer.
2. Open your browser; log in to the CS1708i / CS1716i; and click the
Maintenance icon.
3. Click Browse (to the right of the Firmware File text input box); navigate
to the directory that the new firmware file is in and select the file.
4. Click Upload.
5. After the upload completes, and a message appears on the screen to inform
you that the operations succeeded, logout to exit and reset the CS1708i /
CS1716i.
Note: You will need to wait a bit before logging back in.
72