IBM Nortel Networks L2/3 Manual page 52

Ethernet switch module for ibm eserver bladecenter
Table of Contents

Advertisement

7. If the download location is the same as the location for the currently loaded OS image, the
switch warns you that a failed download could result in an inoperative switch. If the
download location is different from the location of the currently loaded OS image, the
image file downloads. After the download is finished, the switch asks whether you want to
use the old location or the new location. Figure 5-6 on page 37 shows a successful
download of the OS image to image2.
8. Type /boot/reset to reset the switch and reboot with the new firmware files.
Capturing the current configuration
There are a few ways to capture the current configuration in the CLI. The first is to use a
TFTP server to push the configuration file from the switch to the server. However, in some
text editors the resulting file is a single long line of text. (We suggest using WordPad.)
Although this method requires a TFTP server running in the network, it does work with any
Telnet client. To capture the configuration by pushing a file to a TFTP server:
1. Enter /cfg/ptcfg at the command line.
2. Enter the IP address of the TFTP server.
3. Enter the filename to which you want to save the file.
A second way to capture the current configuration does not require a TFTP server. This
method, however, requires a terminal emulator that can capture text. Example 5-1 uses a
Windows® Telnet session to capture the text. The commands on the switch are the same for
any software, but the steps to set the software to capture the text might be different. If your
terminal emulator does not support this, you have to use the TFTP method. Using a Windows
Telnet session and issuing the /cfg/dump command, the full switch configuration can be
dumped.
Example 5-1 Example configuration file dump
>> Main# /cfg/dump
script start "Layer 2-3 Gigabit Ethernet Switch Module for IBM eServer BladeCenter" 4
/**** DO NOT EDIT THIS LINE!
/* Configuration dump taken 2:49:25 Sun Jan 4, 2070
/* Version 1.1.0.6, Base MAC address 00:11:f9:36:b7:00
/c/sys/access/user/uid 1
/c/port INT1
/c/port INT2
/c/port INT3
/c/port INT4
/c/port EXT1
/c/port EXT2
/c/l2/vlan 10
/c/l2/vlan 20
Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
38
name "USERID"
pswd "727ac51410408000ba33a6f7d3f023f2186030e91e4bf6bc15dc8e028cfbe352"
ena
cos admin
pvid 20
pvid 10
pvid 10
pvid 99
tag ena
tag ena
ena
name "VLAN_Green"
def INT2 INT3 EXT1 EXT2
ena