IBM Nortel Networks L2/3 Manual page 136

Ethernet switch module for ibm eserver bladecenter
Table of Contents

Advertisement

/c/l3/vrrp/on
/c/l3/vrrp/vr 1
/* the above is only on GbESM 1; defaults to 100 on GbESM 2
/c/l3/vrrp/vr 2
/* the above is only on GbESM 1; defaults to 100 on GbESM 2
/c/l3/vrrp/vr 3
/* the above is only on GbESM 1; defaults to 100 on GbESM 2
/c/l3/vrrp/vr 4
/* the above is only on GbESM 1; defaults to 100 on GbESM 2
/
/c/l3/vrrp
hotstan ena
/c/l3/vrrp/group
ena
if 50
/* on GbESM 1 only - default to 100 on GbESM 2
prio 101
track
script end /**** DO NOT EDIT THIS LINE!
Example 7-28 Layer 3 Core switch configuration - static routing
! note that VLANs must be created with the Vlan <x> command in "config t" mode
! these statements are not displayed by the "sh run" command
Core1#sh run
Building configuration...
Current configuration : 3019 bytes
!
version 12.2
service config
no service pad
service timestamps debug uptime
service timestamps log uptime
Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
122
addr 10.46.0.246
ena
vrid 1
if 10
prio 101
addr 10.10.0.100
ena
vrid 2
if 20
prio 101
addr 10.20.0.100
ena
vrid 3
if 35
prio 101
addr 10.35.0.100
ena
vrid 4
if 46
prio 101
addr 10.46.0.100
ifs ena