Vd. Controls - Kenmore 630.13952 Manual

Table of Contents

Advertisement

Repair
To remove complete pump
Tools needed: flat blade screwdriver.
1. Use a small flat blade screwdriver to carefully push in the pump housing
latch and rotate the pump clockwise (cw) to remove the pump (1).
2. Disconnect wire harness from pump motor after carefully noting
connections (2).
CAUTION: Don't grab motor next to the capacitor to avoid jamming your
hand on the capacitor.
TIP: Pump motors can have a plastic (newer) or metal (older) housing.
Pumps with plastic motor housings cannot be removed by blocking up
the tank unless the capacitor is removed first (since the capacitor hits the
tank when the pump is rotated).
VD.
Controls
Fascia panel mounted controls
Controls are easily removed from fascia panels by bending console tabs.
Tools needed: T-20 Torx & flat blade screwdrivers.
1. Remove fascia panel by removing T-20 Torx inner door screws.
2. Disconnect wire harnesses from module after noting connector locations.
3. Pry out metal console tabs holding module to console.
4. Carefully pry back plastic tabs, then slide module from console.