JVC DT-V9L5 Instructions Manual page 42

Multi-format lcd monitor
Hide thumbs Also See for DT-V9L5:
Table of Contents

Advertisement

This monitor has two external control terminals.
systems are available.
1)
Controls the monitor by short-circuiting the corresponding pin
terminal to the GND pin terminal, or disconnecting (opening) it.
2)
Controls the monitor by sending the pulse signal instantaneously
to the corresponding pin terminal.
☞ "Using the MAKE/TRIGGER system"on the right
(D-sub 9-pin): Controls the monitor with the
RS-232C system. (☞ "Using the serial communication" on page 43)
Set the following items of "Remote Setting" in Set-Up Menu
according to the external control terminal and control system. (☞
"Parallel Type" on page 38)
Control
Control system
terminal
MAKE/
Parallel Type
TRIGGER
terminal
RS-232C
Serial
terminal
communication
*
1
For a monitor connected to a personal computer etc, select the
terminal the equipment is actually connected to.
"MAKE" takes precedence over other controls.
You can use external control even when "Control Lock" is set to
"Volume Lock" or "All Lock". (☞ page 39)
When the monitor is off (on standby), external control is not
available. But certain external controls (starting/terminating
communication, turning on the monitor) are available through the
serial communication. (☞ page 44)
You can control the monitor by a personal computer or dedicated
controller*
.
2
"Using the MAKE/TRIGGER system" on the right.
*
2
The controller is not commercially available. Consult your dealer if
you need it.
PC, etc.
RS-232C
For the details, see page 43.
42 42
(RJ-45): The following external control
The settings of this unit
"Parallel Type" setting
MAKE
Make
TRIGGER
Trigger
RS-232C
The MAKE/TRIGGER terminal is configured as follows. You can assign
a function to each pin terminal in "Remote Setting". (☞ "Pin1, Pin2,
Pin3, Pin4, Pin5" in "Parallel Type" on page 38)
You cannot change the functions assigned to the pin terminals
from 6th to 8th.
This is a female terminal.
*
1
The 6th pin terminal controls turning on or off the tally lamp
(available to control even when the 7th pin terminal is invalid).
*
2
The 7th pin terminal makes the external control valid/invalid. Keep
the 7th pin short-circuited to 8th pin to make the external control
valid
To assign the functions to the pin terminals
For the operation procedure, see page 31.
Select "Remote Setting" on the Set-Up Menu.
Set "Parallel Type" to "Set."
Select a pin name ("Pin1" – "Pin5") for which you want to assign a
function, then select the function you want to assign.
For the selectable functions, see the table on page 43.
Operation of the external control
Set "Parallel Type" of "Remote Setting" to "Make" or "Trigger" in the
Set-Up Menu.
Keep the 7th pin terminal (Enable) short-circuited to the 8th pin
terminal (GND) so that the monitor can be controlled by the external
control.
When the "MAKE" system is selected: Operate each function by short-
circuiting the corresponding pin terminal to the 8th pin terminal
(GND) or opening it.
When the "TRIGGER" system is selected: Operate each function by
pulse control, that is short-circuiting the corresponding pin terminal
to the 8th pin terminal (GND) for about 1 second and opening it.
When changing the input with MAKE system, activate the pin you
want after deactivating the currently used pin.
When selecting the "TRIGGER" system, you can operate only one
function at a time. Operate the functions one by one.
Pin No.
Pin name
1
Pin1
2
Pin2
3
Pin3
4
Pin4
5
Pin5
6
Tally*
1
7
Enable*
2
8
GND

Advertisement