Ducting Configurations; Ducting Requirements - Jenn-Air JES9800CA Product Dimensions

30" slide-in electric downdraft range
Hide thumbs Also See for JES9800CA:

Advertisement

JENN-AIR
DETAILED PLANNING DIMENSIONS
®
DOWNDRAFT SLIDE-IN RANGE DUCTING ARRANGEMENTS

DUCTING CONFIGURATIONS

5" (12.7 cm)
diameter duct
REAR DuCTING IN WALL TO ROOF
5" (12.7 cm)
diameter duct
REAR DuCTING THROuGH WALL TO OuTSIDE
6" (15.2 cm)
diameter elbow
SIDE DuCTING IN TOE KICK TO OuTSIDE
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
5" (12.7 cm) diameter
to 3
" x 10"
1
4
(8.3 cm x 25.4 cm)
transition elbow
5" (12.7 cm)
diameter wall cap

DUCTING REQUIREMENTS

RANGE
DuCT LENGTH
10' (3.0 m) or less*
Dual Fuel,
Gas
Between 10' (3.0 m)
and 60' (18.3 m)
10' (3.0 m) or less**
Electric
Between 10' (3.0 m)
and 60' (18.3 m)
* Dual fuel ranges must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
** May be used to vent straight out the back of the range and directly through
the wall.
CALCuLATING MAXIMuM DuCTING LENGTH
• Maximum ducting length is 60' (18.3 m).
• Each 90° elbow equals 5' (1.5 m) duct.
• Use no more than three 90° elbows.
• Flexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
• For ducting runs up to 30' (9.1 m), install range as shipped.
• For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the
restricter ring on the blower inlet housing.
• For altitudes above 4500' (1272.0 m), reduce recommended
vent run by 20% for best performance.
5" (12.7 cm)
to 6" (15.2 cm)
diameter
transition elbow
THROuGH FLOOR BETWEEN JOISTS TO OuTSIDE
4 of 4
DuCT SIzE
5" (12.7 cm)
diameter*
6" (15.2 cm)
diameter
3
" x 10"
1
4
(8.3 cm x 25.4 cm)
5" (12.7 cm)
diameter**
6" (15.2 cm)
diameter
3
" x 10"
1
4
(8.3 cm x 25.4 cm)
6" (15.2 cm)
diameter wall cap
JRC120053 03/2012

Advertisement

loading