PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFKB2/P4RFKB12
Capacity
200 Gallons (757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, and Particulate
Class I*; and against
NSF/ANSl
Standard
53 for the reduction
of Live
Cysts, Asbestos,
Lead, Lindane, Toxaphene,
Atrazine,
and 2,4 - D.
This system
has been tested
according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to
the permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Live Cysts t
Asbestos
Lead: @ pH 6.5
Lead: @ pH 8.5
Lindane
Toxaphene
Atrazine
2,4 - D
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
99.95%
99%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
0.07 mg/L
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L
0.140 mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Concentration
2.0 mg/L _+10%
At least 10,000 particles/mL
Influent
Challenge
Concentration
50,000/L rain.
107to 108fibers/L tt
0.15 mg/L + 10%
0.15 mg/L_+ 10%
0.002 mg/L _+10%
0.015 mg/L _+10%
0.009 mg/L_+ 10%
0.210 mg/L_+ 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL**
Maximum
Effluent
54/U
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
Minimum %
Reduction
97
99
Minimum %
Reduction
99.97
99
99.4
98.6
98.9
93
94.5
87.5
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
Average
%
Reduction
97.2
99.4
Average
%
Reduction
99.99
99
99.4
98.6
99
93
94.7
96.1
It is important
that operational,
maintenance,
and filter
replacement
requirements be carried out for the product to
perform as advertised.
Property damage can occur if all
instructions are not followed.
Use replacement
filter P4RFKB2/P4RFI<B12, part #9930.
2013 suggested retail price of $49.99
U.S.A./
$59.99 Canada. Prices are subject to change without notice.
Style 1- When the water filter status display changes from
"GOOD"
to "ORDER," order a new filter. When the filter
indicator
reads "REPLACE," it is recommended
that you
replace the filter.
Style 2 - When the filter indicator
changes from green to
yellow, order a new filter. When the indicator
changes from
yellow to red, it is recommended
that you replace the filter.
Style 3 - When the filter indicator
reads 10%, order a new
filter. When the indicator
reads 0%, it is recommended
that
you replace the filter.
After changing
the water filter, flush the water system. See
"Water
and Ice Dispensers."
These contaminants
are not necessarily
in your water
supply.
While
testing
was performed
under
standard
laboratory
conditions,
actual
performance
may vary.
The product
is for cold water
use only.
The water system must be installed in compliance
with state
and local laws and regulations.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate
disinfection
before or
after the system. Systems certified
for cyst reduction may be
used on disinfected
waters that may contain filterable
cysts.
Refer to the "Warranty"
section in this Use & Care Guide
for the Manufacturer's
name, address and telephone
number.
Refer to the "Warranty"
section in this Use & Care Guide
for the Manufacturer's
limited warranty.
Application Guidelines/Water Supply Parameters
Water
Supply
City or Well
Water
Pressure
30 - 120 psi (207 - 827 kPa)
Water
Temperature
33 ° - IO0°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 gpm (1.9 Lpm) @ 60 psi
%
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark
of NSF International.
35

Hide quick links:

Advertisement