INSTALLATION
GAS HOOK-UP
NATURAL
GAS HOOK-UP
(continued)
To hook-up
the fittings
supplied
with the side burner,
assemble
as shown
in Fig.04.
male threads
only.
Do not use joint
compound
on the flare end of the 1/2" NPT
to 3/8" flare adapter.
Ensure that the regulator
arrow points
in the direction
of gas flow-towards
the unit, away from the
supply.
Do not forget
to place the installer-supplied
gas valve in an
accessible
location.
LP GAS HOOK-UP
CONNECTION:
1/2"NPT
male with
3/8"flare
adapter
(included).
Use 90 ° elbow
1/2"NPTwith3/8"flare
(P/N 212394)
for side mount
models
only when installing
on
the cart.
Use sealer on 1/2" NPT threads
only.
OPERATING PRESSURE: 10.0"W.C.
sideburner
uses theLP
regulator
from adjoining
grill.
Use joint
compound
on
0
_l/2"Coupling
........... 1/2"NPTx2.0"
D
_Nipple
_
Regulator
1/2" NPT x 2.0"
_
Nipple
1/2" NPT to 3/8"
_F
are Adapter
I
To Gas Supply
SUPPLY PRESSURE: 11"to
14"W.C.
FIG. 04 Natural Gas
Apply joint
compound
to the threaded
end of the side burner
gas
inlet and tighten
the adapter
to the pipe.
Assemble
the 24" and 30" hoses to the 3/8" flare tee, as shown
in
Fig.05.
Tighten
the regulator
hose to the remaining
fitting
of the 3/8"flare
tee.
LP TANK
REQUIREMENTS
A dented
or rusty LP gas cylinder
may be hazardous
and
should
be checked
by your
LP supplier.
Never use a cylinder
with
a damaged
valve.
The LP gas cylinder
must be constructed
and marked
in
accordance
with the specifications
for LP gas cylinders
of the
U.S. Department
of Transportation
(DOT) and designed
for
use with
a Type 1 system only.
Do not change the regulator/hose
assembly
from that
supplied
with
the unit or attempt
to use a Type 1 equipped
regulator/hose
assembly
with
a standard
510 POL tank/valve
assembly.
The cylinder
must be provided
with
a shut-off
valve terminating
in an LP gas supply
cylinder
valve outlet
specified,
as applicable,
for connection
Type 1.
If the appliance
is stored
indoors,
the cylinder
must be
disconnected
and removed
from the appliance.
Cylinders
must be stored outdoors
in a well ventilated
area
out of the reach of children.
Gas cylinder
supply
must be turned
off when not in use.
30"Gas
Hose t
Open
Top
Manifold
To
Grill
Manifold
L_:_
ll2"
NPT
t° 3/8" Flare Adapter
I
or P/N 212394
for
Side Mount
only
L P Tank
FIG. 05 LP Gas
11