Gas Hook-Up; Gas Requirements; Natural Gas Hook Up - DCS BGB131 Installation, Use & Care Manual

Professional side burner
Hide thumbs Also See for BGB131:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
GAS HOOK-UP
GAS REQUIREMENTS:
Verify the type of gas supply
to be used, either
natural
or LP. Make sure the marked
gas on the appliance
rating
plate(s) and hook-up
kit agrees with that of the supply.
IMPORTANT!
Never connect an unregulated
gas line to the appliance.
An installer
supplied
gas shut-off
valve must be installed
in an easily accessible
location.
All installer
supplied
parts must conform
to local codes, or in the absence
of local codes, ANSI/NFPS-770-1984.
All pipe sealants
must be an approved
type and resistant
to the actions
of LPgases.
Never use pipe sealant
on flare fittings.
All gas connections
should
be made by a qualified
technician
and in accordance
with
local codes and
ordinances,
n the absence
oflocal
codes, the installation
must comply
with
the National
Fuel Gas Code ANSI
Z223.1.
Gas conversion
kits are available
from the factory.
When ordering,
have the model number,
and the type of
gas (natural
or LP) which
you need.
Total gas consumption
of the professional
side burner
with
burner(s)
on "HIGH"-
Table 1 below.
TABLE 1
MODEL
Btu/hr
BGB131
17,000
BGB132
34,000
BGB131-BI
17,000
BGB132-BI
34,000
The appliance
and its individual
shut-off
valve must be disconnected
from the gas supply
piping
system
during
any pressure
testing
of that system
at test pressures
in excess of 1/2 PSIG (3.5kPa.).
The appliance
must be isolated
from the gas supply
piping
system by closing
its individual
manual
shut-off
valve during
any pressure
testing
of the gas supply
piping
system at test pressures
equal to or less than
1/2
PSIG (3.5 kPa.).
The installation
of this appliance
must conform
with
local codes or in the absence
of local codes, with the
National
Fuel Gas Code, ANSI Z223.1.
Installation
in Canada must be in accordance
with the Standard
CANl-b149
and/or
.2 (installation
code for gas burning
appliances
and equipment)
and local codes.
NATURAL
GAS HOOK-UP:
CONNECTION:
1/2" NPT male with
3/8" flare adapter.
OPERATING PRESSURE: 4.0"W.C.
SUPPLY PRESSURE: 5"to
14"W.C.
If in excess of 14"W.C., a step down
regulator
is required.
Check with your local gas utility
company
or with
local codes for instructions
on installing
gas supply
lines.
Be sure to check on type and size of run, and how deep to bury the line.
If the gas line is too small, the
professional
side burner
will not function
properly.