Zones; Zone Addresses - Honeywell Galaxy 3-48C Installation Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Installation Manual

Zones

The default setting for the zones on the Galaxy 3 Series are shown in the following table:

Zone Addresses

Each zone has a four digit address; 1004, 4136. The address is made up of three reference numbers as shown
in the following figure:
Represents Panel
Line No.
GALAXY
G3 PANEL
1 2 3 4
For example, zone 3057 is the detector connected to line 3, RIO 05, zone 7.
Galaxy
Zone 1001 Zone 1002
Panel
3-48
Final
3-144
Final
3-520
Final
Table 2-6. Default Zone Functions
Example: 3057
3 05
Represents
RIO Address
RIO
ADDRESS 05
Figure 2-11. Zone Addresses
Zone Addresses
Remaining
Zones
Exit
Intruder
Exit
Intruder
Exit
Intruder
7
Represents
Zone No. 1-8 on
RIO
2-13
ZONE 7