Removing A Max Reader From The System; Stand Alone Mode; On-Line Mode; Programming Instructions For On-Line Readers - Honeywell Galaxy 3-48C Installation Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Installation Manual
Keypad Group Restriction: To restrict the operation of the function only to groups that are
common to both the card and the MAX, press the
This means that when a card with access to groups 1, 2 and 3 activates the MAX card function
on a MAX module assigned to groups 2, 3 and 4, the function only operates on the common
groups (groups 2 and 3).
6. Exit engineer mode — engineer code + esc: the keypad displays the message
. LED 2 on the MAX reader switches on. Press the esc key; the keypad returns to the
esc=CONTINUE
unset banner.
If this message is not displayed, the MAX reader is not communicating with the control panel and has not
been configured into the system (LED 2 does not switch on).
NOTES:
1. The MAX reader will not operate until engineer mode is exited and the reader is configured into the
system.
2. All MAX doors must be closed, otherwise engineer mode cannot be exited.
7. The on-line MAX reader is now configured into the system

Removing a MAX Reader from the System

Stand Alone Mode

The stand-alone MAX reader is not connected to the AB line, therefore it can be removed simply by
disconnecting the power to the reader. There is no requirement to access engineer mode.

On-Line Mode

1. Access engineer mode.
2. Disconnect the MAX reader (AB line and power).
3. Exit engineer mode.
The message
1 MOD. MISSING — [<],[>] to View
4. Press the A or B key.
The message
MAX X — =REMOVE MODULE
5. Press the
key to acknowledge and accept that the MAX reader has been removed. The keypad
returns to the unset banner.

Programming Instructions for On-Line Readers

Refer to Section 6: System Operation, menu option 63 = OPTIONS for details on programming the
Open Timeout, Close Timeout and Group parameters for the MAX reader.
NOTE: These programming instructions refer only to on-line MAX readers (modules that are
connected to a host Galaxy panel via the RS485 data bus). For details on stand-alone MAX
installation refer to the MAX Installation and Operations Guide (L120).
For details on the programming of the MAX user cards and functions refer to Section 6: System
Operation, menu option 42 = CODES.
Removing MAX Readers
key when assigning groups to the MAX.
is displayed.
is displayed.
A-5