Resetting Faults; Viewing Active Drive Faults; Rebooting The Drive - Emerson Epsilon EP Drive 400518-01 Installation Manual

Table of Contents

Advertisement

Safety Information
Product Overview
Figure 45:

Resetting Faults

Some drive faults are automatically reset when the fault condition is cleared. Other faults require drive logic power
to be cycled or the drive to be "rebooted". If you wish to continue working in the PowerTools Pro software without
resetting the fault, click the Ignore Fault button.
To reset faults that can be reset with the Reset Faults button, simply click the Reset Faults button in the Drive Faults
Detected dialog box or push the Reset button on the front of the drive where the fault occurred.

Viewing Active Drive Faults

To view all active drive faults, select the View Faults command from the Device menu or by clicking on the View
Faults button on the toolbar. The dialog box displayed is the same as Active Drive Faults Detected dialog box
described above.

Rebooting the Drive

To reboot the drive, cycle power or select the Reboot Drive command from the Device menu. This command reboots
the drive attached to the active Configuration Window.