Motor Brake Wiring - Emerson Epsilon EP Drive 400518-01 Installation Manual

Table of Contents

Advertisement

Safety Information
Product Overview

Motor Brake Wiring

The NT and MG motors equipped with brakes have a three-pin MS style connector. The brake power cable (model
CBMS-XXX) has an MS style connector on the motor end and three wire leads on the drive end (see the following
wiring diagrams). The XV 40-80 mm motors with brakes have a two-position connector. The brake power cable
(model XTBMS-XXX) has a two position connector on the motor end and three wire leads on the drive end. The XV
130 mm motors equipped with brakes have two MS style connectors; one is the encoder feedback and the other has
the motor power and brake connections. The motor power/brake cable (model XCMDBS-XXX) has an MS style
connector on the motor end and six wire leads on the drive end.
You must provide a DC power supply rated at +24 Vdc with a 2 A minimum current capacity for the brake. If you use
this voltage source to power other accessories such as I/O or more than one brake, size the power supply for total
load.
L1
L2
PE
R
S
T
+
_
EP204-I00-0000
9606XX-XX A1
SN 0610E014
Figure 23: Epsilon EP to NT or MG Motor Brake Wiring Diagram
Installation
Installation
Customer
supplied drive
enable contact
Output #3
8
Drive Enable
10
19
I/O Supply
1 Amp
Fuse
I/O Common
20
J3
-
Single point
24 VDC
PE ground
Diagnostics
A1
K1
2 Amp
Fuse
14
Relay:
Model# BRM-1
+
Options and
Accessories
CBMS-xxx Cable
Black -
A2
C
B
A
11
Red +
NT or MG
Motor
Connected to
grounded
mounting panel.
Specification
Internal
to Motor
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents