Analog Command Wiring; Encoder Output Signal Wiring - Emerson Epsilon EP Drive 400518-01 Installation Manual

Table of Contents

Advertisement

Safety Information
Product Overview

Analog Command Wiring

Analog/Sync Output
Connector (J5)
Vdc
Single Point
Panel Ground
Figure 33:
Analog/Sync Output
Connector (J5)
Vdc
Single Point
Panel Ground
Figure 34:

Encoder Output Signal Wiring

The encoder outputs meet RS-422 line driver specifications and can drive up to ten RS-422 signal receivers.
The default encoder output scaling is set to output the actual motor encoder resolutions. The standard MG and NT
motors have 2048 lines per revolution. With PowerTools Pro software this resolution is adjustable in one line per
revolution increments up to the density of the encoder in the motor.
32
Installation
Logic
Common
5
13
External
+
Controller
_
Controller Logic Common
Analog Command, Differential Wiring Diagram
Logic
Common
5
13
External
+
Controller
_
Controller Logic Common
Analog Command, Single Ended Wiring Diagram
Diagnostics
(Internal)
10 Ohm
PE
Single Point
Panel Ground
CW Rotation
+ Command = CW
With positive direction = CW
(Internal)
10 Ohm
PE
Single Point
Panel Ground
CW Rotation
+ Command = CW
With positive direction = CW
Options and
Specification
Accessories

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents