Safety Information
Product Overview
The +/- Travel Limit faults are automatically cleared when the fault condition is removed. The table below lists all the
fault codes in priority order from highest to lowest. This means that if two faults are active, only the higher priority
fault will be displayed.
Display
Diagnostics and Troubleshooting
Installation
Fault
Flash Invalid
Drive Power Up Test
NVM Invalid
Invalid Configuration
Drive Overtemp
Power Module
High DC Bus
Low DC Bus
Reset Button or Input Line on EP-P drive
Encoder State
Reset Button or Input Line on EP-P drive
Encoder Hardware
Diagnostics
Action to Reset
Reprogram the Flash
Cycle Logic Power
Reset Button or Input Line
Reset Button or Input Line
Allow Drive to cool down,
Cycle Logic Power
Reset Button or Input Line
Reset Button or Input Line
Reset Button or Input Line
and
Cycle Logic Power on the other models
and
Cycle Logic Power on the other models
Options and
Specification
Accessories
Bridge Disabled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
43