2.7.2

Using the prtdiag Command

The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
2.7.2.1

Options

TABLE 2-13
help troubleshooting.
Options for
TABLE 2-13
Option
Description
No option
Lists components.
Verbose mode. Displays the
-v
time of the most recent AC
power failure and the most
recent hardware fatal error
information.
describes options for the prtdiag command and how those options can
prtdiag
How It Can Help
Identifies CPU timing and PCI cards installed.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.
Chapter 2