Inner Shield Removal; Input Sensor Removal - Lexmark 10G1664 - T 634dtnf B/W Laser Printer Service Manual

T63 series
Table of Contents

Advertisement

4060-xxx

Inner shield removal

1.
Remove the left door.
2.
Remove the outer system board shield.
3.
Remove all features or option boards from the interconnect board.
Warning: Observe all ESD precautions while handling ESD-sensitive parts. See
4.
Disconnect all cables from the system board.
5.
Remove the inner shield mounting screws (A).
6.
Remove the USB connector mounting screw (B), if present.
7.
Remove the inner shield.

Input sensor removal

1.
Remove the inner paper deflector assembly.
2.
Disconnect the input sensor cable from the input sensor.
3.
Release the input sensor from its mounting and remove.
4-34
Service Manual
ESD-sensitive parts" on page
A
B
See"Outer shield removal" on page
4-1.
A
4-52.
"Handling

Advertisement

Table of Contents
loading

This manual is also suitable for:

T630T632T634T630nT632nT634n