Profiles > Ap > Snmp - Dell PowerConnect W-Airwave Configuration Manual

W-airwave 7.5 configuration guide
Hide thumbs Also See for PowerConnect W-Airwave:
Table of Contents

Advertisement

Table 27
Field
Valid 802.11a 40MHz
Channel pairs
Valid 802.11g 40 MHz
Channel Pairs
Valid 802.11a 40MHz
Channels
Valid 802.11g 40 MHz
Channels
3. Select Add or Save. The added or edited Regulatory Domain profile appears on the Regulatory Domain
Profiles page.
Profiles > AP > SNMP
Dell PowerConnect W-Series controllers and APs support versions 1, 2c, and 3 of Simple Network Management
Protocol (SNMP) for reporting purposes only. In other words, SNMP cannot be used for setting values in a Dell
PowerConnect W system in the current ArubaOS version. Perform these steps to configure a SNMP profile.
1. Select Profiles > AP > SNMP in the Dell PowerConnect W Navigation pane.
2. Select the Add button to create a new SNMP profile, or click the pencil icon next to an existing profile to
edit. Complete the settings as described in
Table 28
Field
General Settings
Folder
Name
Other Settings
SNMP Enable
Enter Community String
Select SNMP User Profile
Select SNMP User
Profile
3. Select Add or Save. The added or edited SNMP profile appears on the SNMP profiles page.
72 | Configuration Reference
Profiles > AP > Regulatory Domain Profile Settings (Continued)
Default
Description
Select a 40MHz channel pair for 802.11a.
A high-throughput (HT) AP can use a 40 MHz channel pair comprised of two adjacent 20
MHz channels available in the regulatory domain profile for your country. When ARM is
configured for a dual-band AP, it will dynamically select the primary and secondary
channels for these devices. It can, however, continue to scan all changes in the a+b/g
bands to calculate interference and detect rogue APs.
Select a 40MHz channel pair for 802.11g
Specify the valid channels for 40MHz channel pairing in 802.11a.
Specify the valid channels for 40MHz channel pairing in 802.11g.
Profiles > AP > SNMP Profile Settings
Default
Description
Top
Set the folder with which the profile is associated. The drop-down menu displays all
folders available for association with the profile.
Blank
Enter the name of the profile.
Yes
Enable or disable SNMP in this profile.
Text field allows you to type one or multiple SNMP community strings applied to this
profile.
If SNMP is enabled in this profile, and one or more profiles have been configured, select
the corresponding SNMP profile from this list.
Table
28:
Dell PowerConnect W-AirWave 7.5 | Configuration Guide