Do not change service data identified as "not used"; they are set as initial settings.
14.3.2 SSSW-SW01:
14.3.2.1 List of Functions
Bit
0
1
2
3
4
5
6
7
14.3.2.2 Detailed Discussions of Bit 0
Selects whether or not service error codes are output.
When output is selected, service error codes is report.
14.3.3 SSSW-SW03
14.3.3.1 List of Functions
Bit
0
1
2
3
4
5
6
7
14.3.3.2 Detailed Discussions of Bit 7
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from overseas.
Memo:
Any of the following error code may be indicated because of an echo at time of reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
#SSSW
0
001
Function
service error code
not used
not used
not used
not used
not used
not used
not used
Function
not used
not used
not used
not used
not used
not used
not used
tonal signal before CED signal transmission
0
0
0
0
0
0
0
F-14-2
T-14-1
1
output
-
-
-
-
-
-
-
T-14-2
1
-
-
-
-
-
-
-
transmit
0
not output
-
-
-
-
-
-
-
0
-
-
-
-
-
-
-
do not transmit
Chapter 14
0016-2002
0016-2003
0016-2004
0016-2005
14-7