Using the integrated management module

The integrated management module (IMM) is a second generation of the functions
that were formerly provided by the baseboard management controller hardware. It
combines service processor functions, video controller, and remote presence
function in a single chip.
The IMM supports the following basic systems-management features:
v Active Energy Manager.
v Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail).
v Auto Boot Failure Recovery.
v Automatic Server Restart (ASR) when POST is not complete or the operating
v Boot sequence manipulation.
v Command-line interface.
v Configuration save and restore.
v DIMM error assistance. The Unified Extensible Firmware Interface (UEFI)
v Environmental monitor with fan speed control for temperature, voltages, fan
v Intelligent Platform Management Interface (IPMI) Specification V2.0 and
v Invalid system configuration (CNFG) LED support.
v Light path diagnostics LEDs to report errors that occur with fans, power supplies,
v Nonmaskable interrupt (NMI) detection and reporting.
v Operating-system failure blue screen capture.
v PCI configuration data.
v PECI 2 support.
v Power/reset control (power-on, hard and soft shutdown, hard and soft reset,
v Query power-supply input power.
v ROM-based IMM firmware flash updates.
v Serial over LAN (SOL).
v Serial port redirection over Telnet or SSH.
v System-event log.
X5.
Search to display the available installation documents.
system hangs and the operating-system watchdog timer times out. The IMM
might be configured to watch for the operating-system watchdog timer and restart
the server after a timeout, if the ASR feature is enabled. Otherwise, the IMM
allows the administrator to generate an NMI by pressing a nonmaskable interrupt
button on the information panel for an operating-system memory dump. ASR is
supported by Intelligent Peripheral Management Interface (IPMI).
disables a failing DIMM that is detected during POST, and the IMM lights the
associated system-error LED and the failing DIMM error LED.
failure, and power supply failure.
Intelligent Platform Management Bus (IPMB) support.
microprocessor, hard disk drives, and system errors.
schedule power control).