At command issuance (I-O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I-O registers setting contents)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
(31)
SECURITY ERASE PREPARE (F3h)
The SECURITY ERASE UNIT command feature is enabled by issuing the SECURITY
ERASE PREPARE command and then the SECURITY ERASE UNIT command.
SECURITY ERASE PREPARE command prevents data from being erased unnecessarily by
the SECURITY ERASE UNIT command.
Issuing this command during FROZEN MODE returns the Aborted Command error.
1
1
1
1
DV
xx
xx
xx
xx
xx
Status information
DV
xx
xx
xx
xx
Error information
C141-E072-01EN
0
1
1
0
xx
xx
The
5 - 57