Fujitsu MPD3XXXAH Product Manual page 115

Fujitsu computer drive user manual
Table of Contents

Advertisement

At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
(28)
SMART (X'B0)
This command performs operations for device failure predictions according to a subcommand
specified in the FR register. If the value specified in the FR register is supported, the Aborted
Command error is posted.
It is necessary for the host to set the keys (CL = 4Fh and CH = C2h) in the CL and CH
registers prior to issuing this command. If the keys are set incorrectly, the Aborted Command
error is posted.
When the failure prediction feature is disabled, the Aborted Command error is posted in
response to subcommands other than SMART Enable Operations (FR register = D8h).
When the failure prediction feature is enabled, the device collects or updates several items to
forecast failures. In the following sections, note that the values of items collected or updated
by the device to forecast failures are referred to as attribute values.
5 - 48
X'98' or X'E5'
DV
xx
xx
xx
xx
xx
xx
Status information
DV
xx
xx
xx
xx
X'00' or X'FF'
Error information
C141-E072-01EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpd3091ahMpd3137ahMpd3182ah

Table of Contents