Test Programs - Fujitsu MBA3073NC Product Manual

Fujitsu computer drive user manual
Hide thumbs Also See for MBA3073NC:
Table of Contents

Advertisement

b. Reporting result of self-diagnostics and error indication
When all specified self-diagnostics terminate normally, the HDD posts the GOOD status for
the SEND DIAGNOSTIC command.
When an error is detected in the self-diagnostics, the HDD terminates the SEND
DIAGNOSTIC command with the CHECK CONDITION status.
The initiator should issue the REQUEST SENSE command when the CHECK CONDITION
status is posted. The sense data collected by the REQUEST SENSE command indicates the
detail information of the error detected in the self-diagnostics.
The HDD status after the CHECK CONDITION status is posted differs according to the type
of the detected error.
a)
When an error is detected in the seek or write/read test, the subsequent command can be
accepted correctly. When the command other than the REQUEST SENSE is issued from
the same initiator, the error information (sense data) is cleared.
b)
When an error is detected in the hardware function test, the HDD posts the CHECK
CONDITION status for all I/O operation request except the REQUEST SENSE
command. The error status is not cleared even if the error information (sense data) is
read. Only when the power is turned off or re-turned on, the status can be cleared. When
this status is cleared, the HDD executes the initial self-diagnostics again (see item (1)).
Refer to Subsection 3.4.1 "SEND DIAGNOSTIC (1D)" of the SCSI Logical Interface
Specifications for further details of the command specifications.
Data loss
When the SEND DIAGNOSTIC command terminates with the
CHECK CONDITION status, the initiator must collect the error
information using the REQUEST SENSE command. The RECEIVE
DIAGNOSTIC RESULTS command cannot read out the error
information detected in the self-diagnostics.
6.1.2

Test programs

The basic operations of the HDD itself can be checked with the self-diagnostic function.
However, to check general operations such as the host system and interface operations in a status
similar to the normal operation status, a test program that runs on the host system must be used.
The structure and functions of the test program depend on the user system requirements.
Generally, it is recommended to provide a general input/output test program that includes SCSI
devices connected to the SCSI bus and input/output devices on other I/O ports.
Including the following test items in the test program is recommended to test the HDD functions
generally.