NEC Express5800/120Ri-2 User Manual page 199

Nec servers user's guide
Hide thumbs Also See for Express5800/120Ri-2:
Table of Contents

Advertisement

8-6 Troubleshooting
Error
Error message
code
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
0B9A
Management controller not responding.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS – SROM data read error.
0BB1
SMBIOS – SROM data checksum bad.
8100
Memory Error detected in DIMM group #1.
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
8103
Memory Error detected in DIMM group #4.
8104
Memory Error detected in DIMM group #5.
8105
Memory Error detected in DIMM group #6.
8160
Mismatch Processor speed detected on
Processor 1.
8161
Mismatch Processor speed detected on
Processor 2.
Recommended Action
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
Turn off the power once and then on again
to restart the server. If the error cannot be
corrected, contact your service
representative.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
Update the RMC firmware. If the error
cannot be corrected, contact your service
representative.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
Contact your service representative.
Contact your service representative to
replace the DIMM in the relevant group.
Contact your service representative.

Advertisement