9.3 Repair Procedures
1. Accessing the interior of the HLZ (Set up for
testing):
a. Disconnect power cord from outlet.
b. Turn unit on its side. Remove the five access screws
located on the bottom of the unit.
c. Then set the unit back down on its base. Place paper
towels on the heater plate to protect it from
scratching. Remove the cowl assembly and lay the
cowl on the heater plate while troubleshooting.
Air heater
relay
Heater Plate
9.4
Replacing Solid State Relays:
a. Avoid miswiring. Examine the terminals carefully and take notes to avoid
miswiring.
b. Remove the plate holding the relay assembly. The nuts holding the relays in place
are easier to reach with the assembly out of the unit.
c. Remove the two nuts holding relays to plate.
d. Apply heat sink compound and install new relay.
e. Reverse this procedure to reinstall.
Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000
Printed in the United States
Heater plate
relay
Front of HLZ
318-865-1711
FAX 318-862-2394
Service Hotline
1-800-24-FRYER
The cowl assembly is held on by five
screws, which are removed from the
bottom of the unit.
The relays are best replaced by removing the plate
that holds them in place. Two 5/16 nuts hold the
plate in place.