E12
ERROR RETURN VALVE NOT OPEN
E13
ERROR RETURN VALVE NOT CLOSED
E14
ERROR AIF BOARD
E15
ERROR MIB BOARD
E16
ERROR AIF PROBE
E17
ERROR ATO PROBE
E18
Not used
E19
M3000 CAN TX FULL
E20
INVALID CODE LOCATION
E21
FILTER
PAD
(Change Filter Pad)
E22
OIL IN PAN ERROR
E23
CLOGGED DRAIN (Gas)
E24
AIF BOARD OIB FAILED (Gas)
E25
RECOVERY FAULT
E26
RECOVERY FAULT CALL SERVICE
E27
LOW TEMP ALARM
PROCEDURE
ERROR
7-6
is missing
Return valve was trying to open and confirmation
is missing
Return valve was trying to close and confirmation
is missing
MIB detects AIF missing; AIF board failure
Cooking computer detects MIB connections lost;
Check software version on each computer.
versions are missing, check CAN connections
between each computer; MIB board failure
AIF RTD reading out of range
ATO RTD reading out of range
Connection between computers lost. Check for
loose CAN cables between computers and MIB
board. Check software version by pressing the
TEMP button with the computers displaying OFF.
If a computer displays only M3000 software, the
computer may be defective.
SD card removed during update
25 hour timer has expired or dirty filter logic has
activated
The MIB has reset the oil in pan flag.
Vat did not empty during filtration
Oil is back sensor failed.
Recovery time exceeded maximum time limit.
Recovery time exceeded maximum time limit for
two or more cycles.
Oil temperature has dropped lower than 15°F
(8°C) in idle mode or 45°F (25°C) in cook mode.
If