5.2

Troubleshooting Guides

NOTE: This guide applies
to FBRA18 units only.
Controller is not functioning.
Probable causes are failed 12V
transformer, failed interface
board, or failed controller.
Call FASC.
No
Probable causes are a failed
interface board or
failed/loose high-level water
sensor wiring.
Problem
resolved.
5-2
COOKPOT DID NOT FILL
WHEN UNIT WAS TURNED ON.
WATER SUPPLY TO UNIT
VERIFIED TO BE ON.
Did anything appear
in controller display when unit
was turned on?
Yes
Open control panel by
removing screws in
each upper corner.
Is WATER
Yes
LED on interface board
illuminated?
No
Use bottlebrush to
clean water level
sensors.
Did LED
No
illuminate?
Yes
Did unit begin
Yes
No
to fill?
Probable causes are a failed
water solenoid or a failed
interface board.