Clean Gas Valve Vent Tube; Check Burner Manifold Pressure - Frymaster Gas Rethermalizers FBR18 Series Installation And Operation Manual

Frymaster gas rethermalizers installation, operation, service, and parts manu
Hide thumbs Also See for Gas Rethermalizers FBR18 Series:
Table of Contents

Advertisement

open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold
the plate in position and retighten the nut(s).

Clean Gas Valve Vent Tube

1. Set the rethermalizer power switch and the gas valve to the OFF position.
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease in removal.
Vent Tube
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any
obstruction.
4. Remove the wire, then blow through the tube to ensure it is clear.
5. Reinstall tube and bend so that the opening is pointing downward.

Check Burner Manifold Pressure

Frymaster recommends that this task be performed by the local gas company or an
1. Ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly and attach the fitting for a gas
pressure-measuring device to the tap.
Regulator Cap
WARNING
authorized service technician only.
4-3
Pressure
Tap Plug