Troubleshooting The Autofill System - Frymaster 17EC Installation, Operation & Service Parts Manual

Frymaster electric cooker installation, operation, service & parts manual
Hide thumbs Also See for 17EC:
Table of Contents

Advertisement

TROUBLESHOOTING THE AUTOFILL SYSTEM

Verify that unit is connected to the
water supply and that water supply
is turned on.
Drain the water in the cookpot to a
level below the upper water-level
sensor.
Place the master ON/OFF switch
in the ON position.
Press the computer ON/OFF
switch.
Did unit
No
begin to fill?
Yes
Did water
shut off when water
reached the upper water-level
sensor?
Yes
Autofill system is OK.
Remove the water-
level sensor guard
and thoroughly clean
the sensors.
Did unit
No
begin to fill?
contactor box 15-pin connector,
check connections and wiring to
connections are intact, the valve
No
6-15
Is voltage across
Pins 2 and 6 of computer
No
15-pin connector zero?
Yes
If 24VAC is NOT present
across Pins 2 and 3 of the
solenoid valve. If wiring and
has failed. Replace.
Yes
Is 24VAC
present across Pins
2 and 6 of the computer
15-pin connector?
Check sensor and wiring.
If they are NOT grounded,
the computer has failed.
Replace.
If they ARE grounded, repair
or replace as required.
Check resistance
through Pins 2 and 9 of
the computer 15-pin
connector. If it is less than 1
ohm, the computer has failed.
No
Replace.
If it is 1 ohm or greater, repair
wiring between sensor and
computer or replace
sensor as required.

Advertisement

Table of Contents
loading

This manual is also suitable for:

17ecsEswEwbs

Table of Contents

Save PDF