6.2
Accessing Equipment for Servicing
Moving this equipment while it is filled with hot water may cause spilling or
splattering of the hot water. Always drain the cookpot before attempting to relocate
1. Disconnect the unit from the electrical power supply and from the water supply.
2. Remove any attached restraining devices.
3. Relocate the unit for service accessibility.
4. After servicing is complete, reconnect the unit to the water supply, reattach restraining devices,
and reconnect the unit to the electrical power supply.
6.3
Replacing Equipment Components
6.3.1
Replacing the Computer
See Section 5.3.
6.3.2
Replacing Electronic Components Other than the Computer
1. Drain the cookpot and disconnect the cooker from the electrical power supply.
2. Remove the covers from the component box. Refer to the illustration below to locate the
component to be replaced.
Delta Power Block
Fuse Blocks
and Fuses
3. On the component to be replaced, make a note of the wiring connection points.
4. Disconnect the wires and remove the failed component. Install the replacement component and
reconnect the wiring in accordance with the notes made in Step 3 or with the wiring diagram on
the door of the unit.
this equipment for servicing.
Transformer
DANGER
Solid State Relays
Master Power Switch
Contactor Block
Basket Lift Relay
6-2