CHECKING BATTERY FLUID
LEVEL
125
250
To check the battery fluid level:
u
Remove the battery cover, see page 63
(REMOVING THE BATTERY COVER).
u
Make sure that battery fluid level is between
the "MIN" and "MAX" marks on the battery.
If not so:
u
Remove the battery caps.
CAUTION
Top up with distilled water only. Do not
exceed the "MAX" mark, because
battery fluid expands when the battery
is under charging.
u
Add distilled water until achieving correct
level.
64
use and maintenance Atlantic 125/250/500 Sprint
CHARGING THE BATTERY
u
Remove the battery, see page
(REMOVING THE BATTERY).
u
Remove the battery caps (
only).
u
Check battery fluid level, see at the side
(CHECKING BATTERY FLUID LEVEL)
(
only).
125
250
u
Connect the battery to a battery charger.
u
Recommended charge rate is 1/10th of
battery capacity.
u
After charging the battery, check battery
fluid level again and top up with distilled
water if needed (
125
250
u
Refit the battery caps (
125
WARNING
When you di sconn ect the battery
charger, allow 5-10 minutes before
refitting the battery, as it will keep
producing gas for a few minutes.
63
125
250
only).
INSTALLING THE BATTERY
only).
250
u
Remove the battery cover, see page 63
(REMOVING THE BATTERY COVER).
u
Refit the battery (1) into its mount.
u
Connect the battery breather pipe (2)
(
125
250
Always connect the battery breather pipe,
to prevent the sulphuric acid vapours from
corroding the electric system, painted
parts, rubber elements or gaskets when
they exit the breather pipe itself (
only).
u
Connect first the positive (+) and then
the negative cable (-).
u
Coat the terminals of cables and battery
with neutral grease or Vaseline.
u
Refit the battery cover, see page
(REMOVING THE BATTERY COVER).
2
1
only).
CAUTION
125
250
63