Technical Data; Dimensional Drawings; General Specifications - Siemens simatic PCIL43 Operating Instructions Manual

Table of Contents

Advertisement

Technical data

13.1

General specifications

13.1
General technical data
Order numbers
Dimensions
Weight
Supply voltage (U
Line voltage frequency
Transient voltage interruption
Power consumption (at 210 W secondary
power)
Max. current output (AC)
Noise emission
Degree of protection
Safety
Protection class
Safety specifications
Electromagnetic compatibility (EMC)
Emitted interference (AC)
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
SIMATIC Rack PC IL 43
Operating Instructions, Edition 09/2005, A5E00432875-01
)
N
6AG4011-2...(for details, refer to the ordering
documentation)
430.4x177.4x444.4 (WxHxD in mm). Detailed
dimensional specifications are found in the "Dimensional
drawings" section.
Approx. 19 kg
100 V AC to 240 V AC (90 to 264 V AC)
50 – 60 Hz
16 ms at 0.85 U
N
(max. 10 events per; min. recovery time 1s)
310 W (efficiency approx. 68%)
+3.3 V/24 A
+5V/26A
max. 190 W total allowed
-12V/15A
+12V/15A
-12V/0.2A
+5Vaux/2A
< 45 dB(A) to DIN 45635
IP 30 with closed front door, IP 20 at the back in
conformity to EN 60529
Protection class I to IEC 61140
EN60950-1, UL60950, CSA C22.2 No 60950-00
EN 55022 Class A, FCC class A
EN 61000-3-2 Class D, EN 61000-3-3
± 2 kV, (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge symm)
± 2 kV; (according to IEC 61000-4-5; Surge asymm)
± 1 kV;(according to IEC 61000-4-4; Burst; length
< 10 m)
± 2 kV, (according to IEC 61000-4-5; Surge symm,
length > 30 m)
13