Administration via optiPoint 500

7.5
Administration via optiPoint 500
Telephone-based administration is only possible at optiPoint terminals with display (i.e. not with
entry, basic and signature).
Note:
>
Only IPadapters on the telephone side may be administrated with optiset E. With IP-
adapters on the system side, initial administration (configuration of the LAN param-
eters) can be implemented via optiset E. However once the operation mode on the
system side is switched, administration is only possible via a web browser.
If, however, you want to connect a telephone without display, then administration must first be
performed with a display telephone. This telephone can then be disconnected.
The administration operation is menu-driven, i.e. all available settings are listed on the termi-
nal's display. You can navigate between the various settings with the dialog keys. Once you
have made all settings, select "Start phone?". The Administration mask closes and a connec-
tion between the terminal and the system is set up. Once optiset E has been started, you can
only access the Administration menu again by unplugging and reconnecting the line (booting
the IPadapter).
Fault signaling:
Faults that occur when operating the optiPoint IPadapter are displayed as follows:
a short signal tone is emitted
all available LEDs on the terminals begin flashing.
If the terminal has a display, an appropriate error message appears on the display. If multiple
faults occur at the same time, the fault with the highest priority is displayed (see the following
diagram).
7-22
Nur für den internen Gebrauch
P31003-E8400-A100-3-7620
Service Manual