Startup

Telephone Tests

3.6
Telephone Tests
Accessing the Telephone Test
The telephone test is started by pressing the "service key" and entering the "code number".
Tests run for approx. 10 s. These are followed by a timeout.
Tests can be stopped at any time by pressing the pound key
Code
Menu text
number
91
LED
92
Screen
93
Keys
94
Audio
941 Speaker
942 Handset
943 Ringer volume
944 Ringer pitch
945 Alerting tone
946 Speakerphone mode Handsfree function (3 levels):
940 Back
95
Asset ID
96
Software version
97
Feeding range
90
Back
Table 3-1
Telephone test for HiPath 4000/Hicom 300 H
optiPoint 500 Models with Display (economy, basic, standard and advance)
You can browse and display individual tests in the Service menu.
Display individual call numbers
Activate LEDs and calls.
Display showing if power supply is sufficient
if sufficient power is being supplied, a light grey pixel pattern is visible
3-4
Action after pressing OK
Start the LED test
Start the screen tests
Start the key test
Go to the audio test/submenu
Test the speaker volume (7 levels)
Test the handset volume (7 levels)
Change the ringer volume (7 levels)
Change the ringer pitch (7 levels)
Change the volume of the alerting tone (7 levels)
normal, loud, noisy room
Return to the audio test
Display the asset ID
Display the telephone SW version
Start the feeding range test
Return to the telephone test